The main parameters of 300kw diesel generator |
|
The model of the unit: |
HL300GF |
Power: |
300KW/375KVA |
Rated voltage: |
230V/400V(adjustable) |
Rated current: |
540A |
Rated frequency: |
50Hz/60Hz |
The factor of rated power |
COS=0.8(lag) |
The regulating rate of steady voltage: |
≤±0.5% |
The regulating rate of instantaneous voltage: |
≤-10%/ +15% |
The time of steady voltage: |
≤1.5sec |
The waving rate of voltage: |
≤0.5% |
The regulating rate of steady frequency: |
≤3% |
The regulating rate of instantaneous frequency: |
≤±5% |
The time of steady frequency: |
3sec |
The waving rate of frequency: |
≤0.25% |
The waste of fuel with full load: |
206g/kw/h |
size(mm): |
3200*1050*1750 |
weight: |
3000KGS |
The main parameters of the engine for 300kw diesel generator |
|
Brand: |
Cummins |
Model: |
NTA855-G2A |
Type: |
four strokes, waste gas turbine boost,direct spurting type |
Cooling way: |
water cooling |
With Type: |
L type |
Bore *Trip : |
140mm*152mm |
Displacement |
14L |
Lubricating oil capacity: |
38L |
Cylinder: |
6cylinders |
Rotating speed: |
1500r/min or 1800r/min |
The regulation of rotating speed: |
Electronic speed |
Starting way: |
DC24V starting with electricity |
The main parameters of alternator for 300kw diesel generator |
|
Brand: |
Stamford,Marathon,Sdanford |
Type: |
brushless (AVR automatic voltage regulating) |
The connecting way of the phase: |
three phases four lines |
Insulation degree: |
H degree |
Grading Protection: |
IP22 |